Top Switch Start up |
|
2013年09月20日 | |
Top Switch's Soft-start    - Top Switch has a fully integrated 17 ms soft-start significantly reduces or eliminates output overshoot in most applications by sweeping both current limit and frequency from low to high to limit the peak currents and voltages during start-up.    - Starting condition is set between multi-cycle-modulation and low frequency mode Limit Output power    - The deliver is “ Po ~ 0.5 * L * I2 * f ”.    - If you set E-Load at CC mode, output demand is full load at start up but the device current limit is set at 25% current limit at this time. It means the Current is constant(0.25* Ilimit), frequency is constant(30KHz), and inductance is constant(User Define) in region 1.    - So the output power(energy) is constant ,you can see the startup will be limited at a DC level.      - If you can't see a DC level ,you need to reconfirm the initial current for your E-Load. Multi-Mode Operation    Multi-mode operation optimizes and improves the power supply efficiency over the entire load range while maintaining good cross regulation in multi-output supplies |