innoSwitch3 UVLO
Line Undervoltage / Overvoltage Sense Resistor
Line Undervoltage
   Set the line sense resistance value based on the brown-in voltage. They are typically connected after the bridge rectifier. Typical total value is 3.8 ~ 4.2 MΩ. RLS is approximately equal to VBROWN-IN × 1.414 / IUV+.
Brown-Out Actual
   During brown-out, the power supply will inhibit switching when the brown-out threshold current falls below the IUV- threshold.
Line Overvoltage
   This is the input AC voltage at which the power supply will instantaneously stop switching once the overvoltage threshold (IOV+) is exceeded, switching will be re-enabled when switching the line overvoltage hysteresis (IOV(H)) level is reached. Line OV voltage is approximately equal to IOV+ × RLS / 1.414.